C-D010 | Description: Hard disk /1 (HDD1) overwrite erase execution. HDD overwrite erase is executed. |
C-1145 | Description: Paper exit alignment motor /Rr (M14) abnormality The paper exit alignment plate home sensor /Fr (PS19) does not turn ON even after a specified period of time after M14 starts the home position search operation. Or, even after a specified per |
C-1509 | Description: SC roller release motor (M18) drive abnormality. The SC roller release operation has not been completed within a specified period of time after M18 turns ON. 35-4 |
C-0118 | Description: Abnormality of the power for the PF drive board (PFUDB) SD/CL of the PF-702/703. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected. |
C-5351 | Description: DC power supply /3 cooling fan (FM36) rotation abnormality 1. The FM36EM error detection signal is detected twice in succession within a specified period of time after FM36 was turned ON. However, error detection signals (24V cut off/blowout |
The most common error codes.
Error | |
---|---|
C-D010 | Description: Hard disk /1 (HDD1) overwrite erase execution. HDD overwrite erase is executed. |
C-1145 | Description: Paper exit alignment motor /Rr (M14) abnormality The paper exit alignment plate home sensor /Fr (PS19) does not turn ON even after a specified period of time after M14 starts the home position search operation. Or, even after a specified per |
C-1509 | Description: SC roller release motor (M18) drive abnormality. The SC roller release operation has not been completed within a specified period of time after M18 turns ON. 35-4 |
C-0118 | Description: Abnormality of the power for the PF drive board (PFUDB) SD/CL of the PF-702/703. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected. |
C-5351 | Description: DC power supply /3 cooling fan (FM36) rotation abnormality 1. The FM36EM error detection signal is detected twice in succession within a specified period of time after FM36 was turned ON. However, error detection signals (24V cut off/blowout |
C-1548 | Description: High temperature abnormality of the top of the glue tank (software detection) The glue tank temperature sensor /Up (TH2) detects an abnormal high temperature. 35-5 |
C-5351 | Description: DC power supply /3 cooling fan (FM36) rotation abnormality 1. The FM36EM error detection signal is detected twice in succession within a specified period of time after FM36 was turned ON. However, error detection signals (24V cut off/blowout |
C-0323 | Description: Paper feed assist fan /Fr1 (FM20) rotation abnormality + 24V power abnormality. The FM20EM error detection signal is detected twice in succession within a specified period of time after FM20 was turned ON. At this time, an error detection si |
C-0506 | Description: 1st tandem PF-703 paper leading edge separation fan /Fr3 (FM11) rotation abnormality. The FM11EM error detection signal is detected twice in succession within a specified period of time after FM11 was turned ON. However, an error detection s |
C-5312 | Description: Suction cooling fan /1 (FM6) power abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, 24V is normal, but an error detection signal (blowout o |