Ricoh IMC6000 Error Code SC569-00

Error Code: SC569-00


Description: Paper Exit/ Pressure Release Motor Error Detection Retry operation fails 3 times consecutively.

Causes: • Pressure roller HP sensor (S26) disconnected • Pressure release encoder modification • Fusing unit defective • Paper exit/ pressure release motor disconnected

Remedy: Inspect the pressure roller HP sensor (S26) with SP5-803-047. If no response from the sensor, perform steps 1 and 2. 1. Check the connection of the pressure roller HP sensor (S26). 2. Inspect the pressure roller HP sensor (S26). 3. Inspect the pr



Ricoh IMC6000 Top Searches

These results are ranked by popularity.

Error
SC687-00Description: PER Not Received Error Unable to receive the PER command from the controller.
SC843-02Description: eMMC rewrite frequency exceeded the threshold (Smart Operation Panel) At startup, or when the machined returned from energy saving mode, the eMMC was read and judged that the number of rewrote blocks had exceeded the threshold.
SC362-01 ... SC362-04Description: SC362-01 TD sensor output error: Lower limit (K) SC362-02 TD sensor output error: Lower limit (C) SC362-03 TD sensor output error: Lower limit (M) SC362-04 TD sensor output error: Lower limit (Y) TD sensor output: Vt (SP3-210-001 to 004) < o
SC665-42Description: Macaron2 Communication Error The machine detects the communication error between CPU and Macaron2 when starting up, or recovery from energy saving mode.
SC727-10Description: Transport Motor Error Motor error (Encoder error) (Jam notification for 1st to 4th times, SC notification for 5th time)

Ricoh IMC6000 Common Errors

The most common error codes.

Error
SC687-00Description: PER Not Received Error Unable to receive the PER command from the controller.
SC843-02Description: eMMC rewrite frequency exceeded the threshold (Smart Operation Panel) At startup, or when the machined returned from energy saving mode, the eMMC was read and judged that the number of rewrote blocks had exceeded the threshold.
SC362-01 ... SC362-04Description: SC362-01 TD sensor output error: Lower limit (K) SC362-02 TD sensor output error: Lower limit (C) SC362-03 TD sensor output error: Lower limit (M) SC362-04 TD sensor output error: Lower limit (Y) TD sensor output: Vt (SP3-210-001 to 004) < o
SC665-42Description: Macaron2 Communication Error The machine detects the communication error between CPU and Macaron2 when starting up, or recovery from energy saving mode.
SC727-10Description: Transport Motor Error Motor error (Encoder error) (Jam notification for 1st to 4th times, SC notification for 5th time)
SC687-00Description: PER Not Received Error Unable to receive the PER command from the controller.
SC843-02Description: eMMC rewrite frequency exceeded the threshold (Smart Operation Panel) At startup, or when the machined returned from energy saving mode, the eMMC was read and judged that the number of rewrote blocks had exceeded the threshold.
SC362-01 ... SC362-04Description: SC362-01 TD sensor output error: Lower limit (K) SC362-02 TD sensor output error: Lower limit (C) SC362-03 TD sensor output error: Lower limit (M) SC362-04 TD sensor output error: Lower limit (Y) TD sensor output: Vt (SP3-210-001 to 004) < o
SC665-42Description: Macaron2 Communication Error The machine detects the communication error between CPU and Macaron2 when starting up, or recovery from energy saving mode.
SC727-10Description: Transport Motor Error Motor error (Encoder error) (Jam notification for 1st to 4th times, SC notification for 5th time)