Error
C9404Description: CIS LED lighting abnormally After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value.
C2152Description: Transfer belt pressure welding alienation • At the completion of transfer belt pressure/retraction operations, the 1st transfer pressure sensor/K (PS51) is not in the status corresponding to each of the transfer belt pressure/retraction oper
C5104Description: Transfer belt motor's failure to turn The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
C2650Description: Main backup media access error • The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value. • MFP detects that the SSD board is
C1130Description: 1st stopper motor’s drive malfunction The 1st folding stopper home sensor (PS603) is not turned ON even after the set period of time has elapsed after the 1st stopper motor (M602) starts searching home posit

Konica-Minolta Bizhub C754e Common Errors

The most common error codes.

Error
C9404Description: CIS LED lighting abnormally After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value.
C2152Description: Transfer belt pressure welding alienation • At the completion of transfer belt pressure/retraction operations, the 1st transfer pressure sensor/K (PS51) is not in the status corresponding to each of the transfer belt pressure/retraction oper
C5104Description: Transfer belt motor's failure to turn The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.
C2650Description: Main backup media access error • The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value. • MFP detects that the SSD board is
C1130Description: 1st stopper motor’s drive malfunction The 1st folding stopper home sensor (PS603) is not turned ON even after the set period of time has elapsed after the 1st stopper motor (M602) starts searching home posit
CD203Description: Memory capacity discrepancy 2. File memory capacity on the printer control board (PRCB) is not enough.
C2650Description: Main backup media access error • The re-written data, which has been read out, checked and founded as error, is read out again and found as error. • The error was found when reading out the counter value. • MFP detects that the SSD board is
C1130Description: 1st stopper motor’s drive malfunction The 1st folding stopper home sensor (PS603) is not turned ON even after the set period of time has elapsed after the 1st stopper motor (M602) starts searching home posit
C9404Description: CIS LED lighting abnormally After a scan job is completed, the machine detected that the average output of the CIS LED is greater than the specified value.
C5104Description: Transfer belt motor's failure to turn The motor lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary.